  PRODUCT SPECIFICATIONS
  E15 Wind Turbine
  PDF (143 KB)

  E Series Wind Turbine
  PDF (46 KB)

Powercorp Alaska has joined with a recognized team of industry leaders to remanufacture the E-15, the worlds most proven wind turbine, to its original specifications. We have updated the controls and made operational improvements to make this one of the most dependable wind turbines on the market today. legged (110 ft)
We stand behind every turbine that we install with an unrivalled system warranty and service structure.


Rotor
Number of blades: 3
Diameter: 50 ft
Swept area: 1964 ft2
Material: Fibergalss reinforced polyester
Pitch: Fixed
Power regulation: Passive stall

Weight:
Rotor: 2,420 lbs
Nacelle: 7,500 lbs
Tower: 6,700 lbs (80ft)
15,050 lbs (110 ft)

Gearbox
Configuration: 3 stage parallel shaft
Gear Ratio: 1:22.4

Yaw System
Friction bearings on geared slew ring with electric worm gear drive (control input from nacelle mounted wind vane)

Brake System
Aerodynamic: Centrifugally actuated blade-tip brakes
Mechanical: Fail safe hydraulic disc brake on low speed shaft

Warranty
1 year parts and labor F.O.B. factory OR
2 years parts and labor with installation and commissioning
Operating Characteristics(35/65kW)
Cut in windspeed: 9 mph
Cut out windspeed: 60 mph
Tip speed: 72 mph / 98 mph
Hub Height: 80 ft / 110ft / 140 ft
Survival windspeed: 100 mph
Rotor speed: 40 rpm / 55 rpm
Regulation: Stall
Orientation: Upwind
Single Phase: 35kW
Three Phase: 65kW


Nacelle
Welded plate steel bed plate (galvanized) with reinforced fiberglass hood

Control
• Remote monitoring and control
• Web based diagnostics
• Integrated into wind-diesel systems


Tower
Height: 80 ft / 110 ft / 140 ft
Material: Hot dip galvanized lattice and tublar
Ladder: Staggered foot pegs for access to exterior man baskets
Safety: Safety cable for harness with fall arresting device
Configuration: 4-legged (80 ft) 3-legged (110 ft)
Safety Systems
• Induction generator has inherent antiislanding
• Centrifugally actuated blade-tip brakes
• Fail safe hydraulic disc brake
• Gearbox heating for cold weather
• Grid monitoring for fault shutdown inputs:
- Line voltage
- Line frequency
- Overproduction
• Over-speed monitoring on hub and generator for fault shutdown
• Thermal protection on generator
• Vibration sensor for fault shutdown
• Automatic cable untwist with emergency override for fault shutdown
• Thermal protection for pump and yaw motor circuits
• 90° nacelle yaw on fault events
• High wind speed fault shutdown